Download PDF of this technology opportunity <pdf>
Biochemical Agent Transport
P
roject goal: Measure the flow field and the dispersion of a Biochemical Agent (BCA) surrogate in the subway station environment to estimate exposure to riders and workers. Future studies will probe the role of forced vs. natural convection on exposure, and methods of BCA containment.
Key Scale Model Features:
135th St station Key PIV Features:
| Model Dimensions | Actual | Model |
| Overall Length |
410’-6” |
8'-6" |
| Distance Between Track & Ceiling | 14'-6" | 3 5/8" |
| Distance Between Platform & Ceiling |
10'-0" | 2 1/2" |
| Tunnel Length Before & After Station | 528’-0" | 11’-0" |
| Train Width | 8'-6" | 2 1/4" |
| Track Width | 10'-5" | 2 5/8" |
| Track Spacing | 1'-6" | 3/8"x3/4" |
| Platform Height | 4'-5" | 1 1/8" |
| Platform Width | 12'-0" | 3" |
| Column Outer Width | 1'x1'x10'-0" | 1/4"x1/4"x2 1/2" |
| Column Inner Width | 1'x1'x15'-0" | 1/4"x1/4"x3 3/4" |
| Spacing to Adjacent Column | 15'-0" | 3 3/4" |
| Staircase Dimensions | ||
| Overall Height | 10'-0" | 2 1/2" |
| Footprint Width | 6'-6" | 1 5/8" |
| Footprint Length | 15'-6" | 3 7/8" |
| Distance to Adjacent Staircase | 102'-0" | 2'-1 1/2" |